Offering well engineered Flame Arresters, In-Line Flame Arresters, End of Line Flame Arresters, Breather Valves, Emergency Vents, Hatches, etc....
INTRODUCTION
/ ABOUT US
Providing
safety and environmental solutions to various industries has been the
sole objective of Kingsley Engineering Services ever since its
establishment in the year 1996. We are recognized as an eminent
manufacturer, exporter and supplier of
Flame Arresters, Breather
Valves, Emergency Vents, Gauge Hatches, Vacuum Breakers, Pressure
Releasing Valves, and Safety Valves.
Fabricated using A-grade
raw materials, our products are an epitome of strength and
durability. Owing to the superior quality of the products offered by
us, we have been accredited with the much coveted ISO 9001:2000
certification. We have made our presence felt in the domestic as well
as the international arena, and our products are regularly exported
to the Gulf countries, Thailand, Malaysia and many other countries
worldwide.
Breather
Valve/ Pressure Vacuum Vent Valve
A
Breather Valve
helps storage tank/vessel for breathing, In and Out. These are mainly
designed to prevent Vapor losses due to Evaporation, Over Pressure,
Storage buckling, negative pressure (Vacuum).
We
manufacture Breather
Valves to
suit various chemical conditions, temperature and blanketing systems.
In case of any increase in pressure inside the storage tank, due to
any operational or climatic change, the installed Breather Valve
releases the excessive raised pressure inside the storage tank, and
thus the pressure is balanced to normal/required. While withdrawing
the liquid, from the storage, a vacuum/negative pressure might be
created inside the storage tank. Any such vacuum/negative pressure,
created inside the storage tank can hold the liquid from pumping out
or buckling the storage tank. In both the cases (Increase/ Decrease
of pressure) Breather
Valve play
very important role in the total system.
Breather
Valves
are designed in accordance to API 2000 Standard. For high Pressure/
Vacuum applications, spring loaded Breather Valves can also be
furnished. In case the vapors of the stored fluid are of
polluting/hazardous nature, flanged unit can be provided, which can
convoy through inlet & outlet tubes, these vapors in a safety
zone.
Emergency
Vent
Mainly
these vents are mounted as secondary relief devices, in any case, if
the breather valve installed on the storage is not capable to relive
the sudden raised pressure, the installed Emergency Vent acts and
releases the sudden overpressure condition. Normally the EMERGENCY
VENTS are designed from 14 inch -36 inch
in size. EMERGENCY VENTS above
18 inch sizes
are also used as MAN HOLE to the storage at shut
downs.
MOC
of the vents are designed, Cast Steel, Stainless Steel & Aluminum Body depending upon application. MOC can be changed in
special material as per the customer requirement. Non contact sealing material is used to assemble the venting DEAD WEIGHT, Neoprene rubber sheet is used to back the PTFE.
After calibrating the BREATHER VALVE, calibration of this vent is done. Calibration process could also be done along with the breather valve, depending on the level of hazard which the gases and vapors may cause.
Vacuum Breaker
In
certain applications protection from vacuum is required, in such
conditions a vacuum breaker is used. Vacuum Breaker can be installed
in the pipelines or storage tanks. A Vacuum Breaker intakes the
atmospheric air and avoids any vacuum creation condition into the
piping or storage system.
Click To Download